Filter Results By:

Products

Applications

Manufacturers

Signal Sources

Instrument that provides a stimulus signal (waveform). (www.tek.com)

See Also: Signal, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Conditioning, Signal Generators, Signal Meters, Signal Conditioners


Showing results: 526 - 540 of 657 items found.

  • Optical Signal Test Set

    OST - Spectronix

    The Optical Signal Test Set (OSTS) combines a state of the art optical power meter, a variable attenuator, and a high stability laser source.  The unit is able to measure optical signals below -100dBm with 0.001dB resolution at a fraction of the size, power, and cost of competing solutions.   Other features include data logging, programmable filtering, and auto calibration.  Its small shielded ruggedized package, USB/power interface, and low cost make this unit perfect for lab use or for integration into larger systems.

  • Three-Phase Relay Protection Tester

    GDJB-PC - Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd

    1.GDJB-PC Universal Secondary Injection Relay Test Set is applied to test the relay unit in relay protection system. 2.At the same time GDJB-PC Universal Secondary Injection Relay Test Set could be considered as a universal three phase AC/DC voltage source or current source. 3.It can work alone or connected to computer, inside the relay controller there are new speed digital signal mini PC and real DAC (Digital-to-Analog Converter) template with new high fidelity and high power, the machine has large panel screen and rotating mouse. It is small in volume, high precision.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • Electronics

    WIKA Alexander Wiegand SE & Co. KG

    Many force measurement applications can be complemented by electronic components. To ensure that all system-relevant components come from a single source, WIKA continuously expands its product range with useful electronics. WIKA offers controllers, amplifiers, limit switches, hand-held measuring instruments, digital indicators and electronic accessories that ensure trouble-free operation. With the help of electronics matched to the measuring components, set limit values are maintained and checked with the reading instruments. Amplifiers are available with analogue and digital output signals. The LED display or LCD are available with 4 or 6 digits.

  • Ethernet Digital Interface

    Model 8063 - ICS Electronics

    * Provides 48 high-power TTL I/O lines that can sink 48 mA or source 24 mA. * Easily interfaces to TTL or CMOS signals and contact closures. * User can configure the data bytes as inputs or outputs.* Transfer data as bits, bytes or data strings.* Transparent data transfer mode.* Fully VXI-11 Compliant plus Raw Socket for easy programming with Visual Basic or C, Agilent VEE and LabVIEW.* 1 U high rack mount kit mounts one or two 8063s.* Includes 100-230 VAC Power Adapter with universal plugs.

  • Radio Trigger Module

    RTM3 - Seismic Source Co.

    The Remote Trigger Module 3, or RTM3 3, is a new generation of impact trigger device. It is designed to time synchronize a single seismic source unit with multiple seismic recorders. It can also be used to synchronize multiple seismic recorders. The RTM3 units use an internal high accuracy oscillator that is synchronized to GPS timing information. Each RTM3 unit requires an external GPS receiver with valid satellite information to synchronize the internal clock. Once the internal clock is synchronized the RTM3 can be used without any GPS signal for up to 10 minutes.

  • Universal Calibrators

    Mugdha Controls

    We offer our clients an exclusive range of Universal Calibrators which is designed and manufactured by our technical team. Our range is designed using superior quality material, and is widely appreciated for its rugged designs and durability. Also, these are presented with dual operating ability of source & sink of signals that make them appropriate for labs and process plants. Further, our assortment is extensively used in the calibration of instruments, commissioning of field instruments, repair & maintenance of filed instruments and as millimeter with limited facilities in various industries, such as chemical, cement, textile, fertilizer and automobile.

  • TimerBlox

    Analog Devices Inc.

    Analog Devices TimerBlox parts are small, accurate, and simple timing devices designed for six basic operations: voltage controlled oscillation (VCO), low frequency clocking, pulse-width modulation (PWM), one-shot generation and signal delay, and power-on reset (POR). TimerBlox devices combine an accurate programmable oscillator with precision circuitry and logic. No capacitors, no crystals, no microcontroller, and no programming are required. A 20 mA source and sink capability enables the devices to directly drive opto-isolators and transformers for electrical isolation. An ideal solution for space-limited applications, each TimerBlox device can be placed at the point of use.

  • Precision I/V Source

    Model 155 - Lake Shore Cryotronics, Inc.

    To reliably characterize developing semiconductor materials and devices, you need high quality current or voltage sources to excite samples. A cleaner (i.e., lower noise) excitation signal enables better measurement of the sample’s response. The MeasureReady™ Model 155 precision I/V sources are ideal for electronic material characterization and other demanding scientific applications requiring a precise, low-noise supply of current or voltage. Supplying 1 W maximum from DC to 100 kHz over a broad output range, these sources provide a solid foundation for I/V curve, Hall effect, and other fundamental measurements. With online software updates, your instrument will always have the most current capabilities. As Lake Shore introduces new options in the future, you can purchase and download them to your instrument. This allows the Model 155 to grow as your measurement needs evolve.

  • Broadband Threshold Detectors

    KRYTAR, Inc.

    KRYTAR's All NEW Broadband Threshold Detectors are hermetically sealed for high reliability and are specifically designed for use in today's high-performance microwave instrumentation and systems. KRYTAR detectors are designed for such applications as power measurements, analyzing radar performance, leveling pulsed signal sources, AM noise measurements, system monitoring and pulsed RF measurements in ultra-broadband and mm-Wave applications.

  • Microwave / RF Synthesizers, Test & Measurement

    Berkeley Nucleonics Corporation

    The 825-M is an agile ultra-low phase noise RF signal source from 8 kHz to 20 GHz RF Synthesizer. It is available in single-channel or multichannel configurations. A single channel 825-M is packaged in a compact enclosure, or can be ordered with a touch-screen display, or a 1U 19" rackmountable version. The multi-channel version (2, 3, or 4 channels) is packaged in a 19” 1U rackmount enclosure.

  • Digital Recorder

    HiRES - HIGHVOLT Prüftechnik Dresden GmbH

    The digital recorders HiRES are used to measure, store, and evaluate signals from up to 64 sources synchronously. Depending on the sensors used voltages, currents, temperatures, mechanical movements and various other signals can be measured. This measurement system features the ability to capture fast transient processes such as those occurring in impulse current tests on electrical devices or during switchgear testing. The system is also capable of measuring semistationary and periodic events such as DC voltage and AC voltage as well as superimposed semistationary, periodic and transient processes.

  • PNA-X Network Analyzers

    Keysight Technologies

    Keysight's PNA-X is more than just a vector network analyzer. It is the world’s most integrated and flexible microwave test engine for measuring amplifiers, mixers, frequency converters, and other active devices. The hardware includes two internal signal sources, a signal combiner, S-parameter and noise receivers, pulse modulators and generators, and a flexible set of switches and RF access points. These hardware features provide a powerful core for a broad range of linear and nonlinear measurements, all with a single set of connections to your device under test.

  • Frequency Converter

    FC5-29M - Elmika

    Frequency converter FC5-29M is a measurement instrument which is designed for spectrum conversion of 75 - 170 GHz to 1 MHz ÷ 2,6 GHz range and automatic frequency measurement of sinusoidal signals. When combined with the 1 MHz - 3,0 GHz spectrum analyzer, FC5-29M can be used for examination of the continuous and periodically repeating pulse signals.The instrument is meant to be used for measurement of various signal sources, radio-transmitting instruments, synthesizers, frequency converters, measurement generators and also for adjustment and verification of various radio-transmitting or communication instruments in laboratory and workshop conditions.

  • Low Noise Pre-Amplifiers

    Praxsym

    Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.

Get Help